Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL  (2023)

Autori:
Pedrotti, Emilio; Bonacci, Erika; Kilian, Raphael; Pagnacco, Camilla; Anastasi, Marco; Ventura, Mariacarmela; Marchini, Giorgio
Titolo:
Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL
Anno:
2023
Tipologia prodotto:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Lingua:
Inglese
Formato:
Elettronico
Referee:
Nome rivista:
FRONTIERS IN MEDICINE
ISSN Rivista:
2296-858X
N° Volume:
10
Numero o Fascicolo:
1085280
Intervallo pagine:
1-6
Parole chiave:
cataract; extended depth of focus IOL; near vision; premium IOLs; spectacle independence
Breve descrizione dei contenuti:
Purpose: To analyze the objective and subjective visual performances of a new hybrid refractive/aspheric extended depth of focus (EDOF) intraocular lens (IOL). Methods: In this monocentric prospective study patients with bilateral cataracts underwent cataract surgery and were implanted with a Lucidis IOL (SAV-IOL SA, Neuchâtel, Switzerland) in both eyes, 1 week apart from each other. At 3 months from implantation postoperative evaluations included monocular and binocular uncorrected and distance-corrected distant (4 m), intermediate (80 cm, 67 cm) and near (40 cm) visual acuities (UDVA/DCVA, UI80-67VA/DCI80-67VA, UNVA/DCNVA), binocular defocus curves, halometry, contrast sensitivity and objective quality-of-vision measurements. Also, patients were also asked to complete the national eye institute refractive error quality of life (NEI-RQL-42) questionnaire. Results: Twenty-five patients (50 eyes) were included. The mean postoperative binocular UDVA, UI80VA, UI67VA and UNVA were-0.02 ± 0.13, 0.05 ± 0.09, 0.05 ± 0.08 and 0.03 ± 0.1 LogMar, and did not significantly differ from their corrected counterparts. On binocular defocus curves a VA ≥0.05LogMar was found between +0.50 and - 2.50 D of vergence, whereas the mean distance from the central stimulus on halometry was 1.23 ± 0.01. Mean ocular and corneal radical mean square at 4 mm were 0.31 ± 0.28 and 0.19 ± 0.07, respectively; whereas the mean Strehl ratio was 0.2 ± 0.09. Conclusion: Lucidis IOLs demonstrated excellent visual performances, especially at close distances while maintain good quality of vision, contrast sensitivity, and overall patient-satisfaction.
Note:
Emilio Pedrotti and Erika Bonacci have contributed equally to this work
Pagina Web:
https://doi.org/10.3389/fmed.2023.1085280
Id prodotto:
133108
Handle IRIS:
11562/1089986
ultima modifica:
28 aprile 2023
Citazione bibliografica:
Pedrotti, Emilio; Bonacci, Erika; Kilian, Raphael; Pagnacco, Camilla; Anastasi, Marco; Ventura, Mariacarmela; Marchini, Giorgio, Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL «FRONTIERS IN MEDICINE» , vol. 10 , n. 10852802023pp. 1-6

Consulta la scheda completa presente nel repository istituzionale della Ricerca di Ateneo IRIS